top of page

Price includes the following:

*A Bryant Legacy 1.5 Ton 14 SEER Air Conditioner Model # 114CNA0180L0 or a Bryant Legacy 1.5 Ton 16 SEER Air Conditioner Model # 116BNA018000a depending on choice selection in the SEER dropdown.

*One of the 2 following Bryant/Carrier Evaporator Coils (Vertical application only) 

*Model # CNPVP1814ALA (14.1875 inch wide/ 12.625 inch high)

*Model # CNPVP1917ALA (17.5 inch wide/17 inch high)

 One of the following Bryant Condensing Gas Furnace (Vertical application only)

*Model # 915SB30040E14 (14 inch wide 40,000 btu input)

*Model # 915SB36040E17 (17.5 inch wide/35 inch tall, 95 % AFUE 40,000 btu input)

*Model #926TB30040V14 (14 inch wide/35 inch tall, 96 % AFUE 40,000 btu input)

*Model # 926TB36040V17 (17.5 inch wide/35 inch tall 96% AFUE 40,000 btu input)

*Removal of old refrigerant from existing equipment (Refrigerant recovery)

*Removal and haul away of old air conditioner and related debris

*Removal and haul away of old evaporator coil and related debris

*Removal and haul away of olf furnace and related debris

*New 30x30 inch air conditioner pad

*Leveling ground for new 30x30 inch air conditioner pad

*Placement of New Bryant 1.5 ton air conditioner on new 30x30 inch air conditioner pad 

*Copper refrigerant pipe connections right at the air conditioner and right at the evaporator coil using the existing lineset(refrigerant pipes). 

*R11 flush to clean out old refrigerant and oils out of the existing lineset 

*Copper refrigerant fittings needed to connect air conditioner and evaporator coil to existing lineset

*New black rubbatex insulation for suction pipe up to 6 feet at the air conditioner and up to 6 feet at the evaporator coil

*3/8 single direction filter drier

*Brazing by use of Oxy/Acetylene torch and low pressure nitrogen

*Nitrogen pressure test 

*Evacuation by use of vacuum pump

*High and low voltage wiring connections at air conditioner

*High and low voltage wiring connections at the furnace

*Gas pipe connections at furnace 

*Sheet metal duct transition at evaporator coil up to 1.5 feet in height only in accessible areas

*Silver taping at the top and bottom of the evaporator coil

*Silver taping at furnace/coil connection and furnace and return duct connection

*Silver taping duct joints for new duct transition or box if required to make transition or box

*Condensate drain piping for the evaporator coil and furnace using 3/4-inch pvc pipe and fittings up to 10 feet

*Reconnect flu pipe to new furnace

*Open service valves

*Test A/C

*Test Heat 

*Add additional 410a refrigerant as needed to reach optimum subcooling and superheat levels

*PRICE INCLUDES INSTALLATION AND LABOR COST

 

1.5 Ton Bryant Legacy Air Conditioner, Evaporator Coil w/ Condensing Furnace

$8,683.00Price
  • 1-3 day Delivery and Installation 

    Call us now to check our availability and to schedule installation!

    (828)-301-4875

    Or email us at: 

    drymountairwnc@gmail.com

Product Page: Stores Product Widget
bottom of page